Project Login
Registration No:
Password:
MAIL ALERTS SMS ALERTS
 
     
   
     

SUPREMACY LINE LIABILITY AND SCRUTINY IN 3 PHASE INDUCTION MOTOR

Platform : EMBEDDED

SUPREMACY LINE LIABILITY AND SCRUTINY IN 3 PHASE INDUCTION MOTOR

 

ABSTRACT

 

 

 

The power line faults (3Phase) such as phase-to-phase fault and phase to earth fault can be monitored in this project. The data from various zones can be collected and the corresponding zones can be isolated and information can be given in a intelligent LCD display. The whole work is done with the help of 89c51 controller. The controller processes the various inputs and displays it. When necessary the fault analysis can also be done during open & short circuit conditions using this project.

 

Distribution networks are typically of two types, radial or interconnected. A radial network leaves the station and passes through the network area with no normal connection to any other supply. This is typical of long rural lines with isolated load areas. An interconnected network is generally found in more urban areas and will have multiple connections to other points of supply. These points of connection are normally open but allow various configurations by the operating utility by closing and opening switches. Operation of these switches may be by remote control from a control centre or by a lineman. The benefit of the interconnected model is that in the event of a fault or required maintenance a small area of network can be isolated and the remainder kept on supply.

 

This technology helps to check the power distribution and monitoring, normally the power stations are distributed the power in main areas this 3 phase power again distributed by substation. Some time any one trunk line goes failure the particular line area get affected  but our project concept or our design switch to other feeder same phase to failure line or more two phase failure our system intimate to the particular in charge Through RF technology by using some alarm. The RF frequency range 27 MHz.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLOCK DIAGRAM;

 

 

 

  • Block Diagram

 

 

 

 

 

 

 

 

 

 

 

        ATMEL

         89C51

 

        MICRO-

  CONTROLLER

 

 

 

 

  PHASE-B

 

 

 

 

  PHASE-Y

 

 

 

 

 PHASE-R

 

POWER LINES

 

 

 

 

 

 

         
     
 
   

CONTACTOR

 
   
 

 

 

 

 

 

 

 

 

 

 

 

 


 

 

 

Relay

 

                                   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

               

 

 



NOW GET PROJECTS ! GET TRAINED ! GET PLACED !

IEEE, NON-IEEE, REAL TIME LIVE ACADEMIC PROJECTS,

PROJECTS WITH COMPLETE COURSES,SOFT SKILLS & PLACEMENTS

ALLOVER INDIA & WORLD WIDE,

HOSTEL FACILITY AVAILABLE FOR GIRLS & BOYS SEPARATELY,

CALL: 08985129129 ,  E-Mail Id: support@ascentit.in

REGISTER FOR PROJECTS NOW ! GET DISCOUNT
   
1